With or Without Thermostat Control

EXAIR Cabinet Coolers are available with or without thermostat control. The continuous coolers (Model 4200 and 4700 series) are recommended when constant cooling and a constant positive purge are desirable. The thermostatically controlled systems (Model 4300 and 4800 series) save air by activating the cooler only when internal temperatures approach critical levels. The adjustable thermostat is factory set at 95°F (35°C). Thermostatic systems are recommended where heat load fluctuates and continual purge is not required.
A dangerous shock hazard exists when the panel door is opened to let a fan blow hot, dirty shop air at the electronics.
A dangerous shock hazard exists when the panel door is opened to let a fan blow hot, dirty shop air at the electronics.

All EXAIR Cabinet Cooler Systems contain a 5 micron Automatic Drain Filter for the compressed air supply and a Cold Air Distribution Kit to circulate the cold air throughout the enclosure.


Environmental Considerations
NEMA 12 (IP54) Cabinet Coolers (dust-tight, oil-tight) are ideal for general industrial environments where no liquids or corrosives are present.

NEMA 4 (IP66) Cabinet Coolers (dust-tight, oil-tight, splash resistant, indoor/outdoor service) incorporate a low pressure relief valve for both the vortex tube and cabinet air exhaust. This valve closes and seals when the cooler is not operating, to maintain the integrity of a NEMA 4 enclosure.

NEMA 4X (IP66) Cabinet Coolers (corrosion resistant) offer the same protection as NEMA 4, but are constructed of 304 stainless steel for food service, pharmaceutical and corrosive environments.


Cabinet Cooler Specifications

Cabinet Cooler Specifications
NEMA 12
(IP54)
(Dust, oil resistant)
Model # Capacity Btu/hr. Capacity Kcal/hr. Thermostat Control Sound Level dBA
4208 550 139 No 67*
4215 1000 252 No 73*
4225 1700 428 No 74*
4230 2000 504 No 74*
4240 2800 706 No 78*
4250 3400 857 No 75*
4260 4000 1007 No 77*
4270 4800 1209 No 77*
4280 5600 1411 No 79*
4308 550 139 Yes 67*
4315 1000 252 Yes 73*
4325 1700 428 Yes 74*
4330 2000 504 Yes 74*
4340 2800 706 Yes 78*
4350 3400 857 Yes 75*
4360 4000 1007 Yes 77*
4370 4800 1209 Yes 77*
4380 5600 1411 Yes 79*
NEMA 4
(IP66)
(Splash resistant)
4708 550 139 No 67
4715 1000 252 No 73
4725 1700 428 No 80
4730 2000 504 No 80
4740 2800 706 No 82
4750 3400 857 No 84
4760 4000 1007 No 84
4770 4800 1209 No 84
4780 5600 1411 No 85
4808 550 139 Yes 67
4815 1000 252 Yes 73
4825 1700 428 Yes 80
4830 2000 504 Yes 80
4840 2800 706 Yes 82
4850 3400 857 Yes 84
4860 4000 1007 Yes 84
4870 4800 1209 Yes 84
4880 5600 1411 Yes 85
NEMA 4X
(IP66)
(Corrosion resistant)
(Available in 316SS)
4708SS 550 139 No 67
4715SS 1000 252 No 73
4725SS 1700 428 No 80
4730SS 2000 504 No 80
4740SS 2800 706 No 82
4750SS 3400 857 No 84
4760SS 4000 1007 No 84
4770SS 4800 1209 No 84
4780SS 5600 1411 No 85
4808SS 550 139 Yes 67
4815SS 1000 252 Yes 73
4825SS 1700 428 Yes 80
4830SS 2000 504 Yes 80
4840SS 2800 706 Yes 82
4850SS 3400 857 Yes 84
4860SS 4000 1007 Yes 84
4870SS 4800 1209 Yes 84
4880SS 5600 1411 Yes 85