Contact US
Industrial Housekeeping

How The Chip Trapper™ Works

How The Chip Trapper Works

The vacuum hose (1) is attached to the barbed connection of the Chip Trapper (2). The directional flow control valve on top of the drum (3) and knob on the pump (4) are set to the “fill” position. The air supply valve is opened to permit compressed air at 80-100 PSIG (5.5 – 6.9 BAR) to flow through the pump which pulls the liquid through the hose, then into the reusable filter bag (5). When all liquid is in the drum, the air supply is turned off. The filtered liquid can then be pumped out by setting the directional flow control valve on top of the drum and knob on the pump to the “empty” position. Once the air supply valve is opened, the air pushes the liquid back through the hose while all solids remain in the reusable filter bag.


CAD Library CAD Library PDF Library PDF Library Presentations Presentations
Videos Videos FAQs FAQs
QUICK ORDER:
CART INFORMATION:
APPLICATION SEARCH:
 
 
 
 
 
Bookmark and Share
 
  Follow Us
  RSS Wordpress Twitter Facebook