Contact US
Optimization

Intelligent Compressed Air Product

Digital Flowmeter™

with wireless capability


Monitor compressed air usage and waste!

Digital Flowmeter with wireless capabilityWhat is the Digital Flowmeter with wireless capability?
EXAIR’s Digital Flowmeter with wireless capability is available as a built in option for EXAIR digital flowmeters. The easy way to monitor compressed air consumption and waste can now be done wirelessly over a ZigBee® mesh network! A radio module within each meter transmits data to an Ethernet connected gateway. Using the ZigBee mesh network protocol, data can be passed from meter to meter to extend the distance over which the wireless system can operate. Each meter has a range of 100' (30 meters). Setup is simple and consists of installing or retrofitting a meter, installing EXAIR's wireless-to-Ethernet gateway and running the graphing software available from our website. Many companies install the Digital Flowmeter on each major leg of their air distribution system to constantly monitor and benchmark compressed air usage.

Why the Digital Flowmeter with wireless capability?
The Digital Flowmeter with wireless capability includes a wireless output flowmeter and a wireless-to-Ethernet gateway for new installations. They are also available without a gateway if adding a meter to a gateway already existing in your plant. EXAIR simplifies the process by configuring each gateway to communicate with the flowmeter(s) to provide the necessary communication for monitoring your system. Models from 1/2" to 4" iron pipe are in stock. Each Digital Flowmeter is calibrated for the pipe size to which it is mounted. The large digital display shows air use in either SCFM or Cubic Meters per hour.CE and RoHS Compliant

The Digital Flowmeter with wireless capability is designed for permanent or temporary mounting to the pipe. It requires the user to drill one or two small holes through the pipe using the included drill bit and locating fixture. The two flow sensing probes of the flowmeter are inserted in these holes. The unit seals to the pipe once the two clamps are tightened. No cutting, welding, adjustments or calibration are ever required. If the unit needs to be removed, blocking rings are available. NEMA Type 4 (IP66) meters are available. Consult the factory.

Advantages
  • Provides wireless monitoring of EXAIR flowmeters throughout a plant
  • Configured to prevent unwanted joining upon the network
  • Monitoring software provided at no charge
  • Utilizes mesh networking protocol to relay data from remote meters
  • Transmits current air usage and cumulative air usage data
  • 128 bit encryption for wireless transmissions
  • Identify areas with high compressed air use
  • Models from 1/2" to 4" Schedule 40 iron pipe in stock
  • Models are also available for 5" and 6" in iron pipe
  • Models are available for sizes 3/4" to 4" in copper pipe
  • Easy to install
Digital Flowmeter with wireless capability
A Digital Flowmeter with wireless capability includes
24 VDC power supply with adapters, 3/16" drill bit,
ethernet cable and locating fixture.

Specifications

Accuracy

5% of reading, plus 1% of full scale for air temperatures between 40º to 120ºF (4º to 49ºC).

Operating Pressure

30 to 140 PSIG for best accuracy - 200 PSIG max.

Input Power

250 mA at 24 VDC / Power Adapter included 100-120VAC

Wetted Materials

Stainless steel, gold, thermal epoxy and Viton (seal)

Ring Material

Aluminum

Display

Four-digit LED display

Compliance

CE and RoHS

EXAIR Logger

Download here

Device Discovery Software

Download here


Note: For use with compressed air and nitrogen only.

Dimensions*

*If dimensions are critical for mounting, please consult the factory.

Digital Flowmeter with wireless capability dimensions A
Series Pipe
Size
in mm
9090Z 1/2" 3.28 83
9091Z 3/4" 3.46 88
9092Z 1" 3.84 97
9094Z 1-1/2" 4.59 117


Digital Flowmeter with wireless capability dimensions A
Series Pipe
Size
in mm
9095Z 2" 4.88 124
9096Z 2-1/2" 5.75 146
9097Z 3" 6.38 162
9098Z 4" 7.38 187

 

Gateway Dimensions

Gateway Dimensions

 

Buy Now Digital Flowmeter with Wireless Capability and Gateway
Pipe Size/SCFM/M3 Range**
9090ZG  1/2" (Schedule 40 iron) 1–90 SCFM (2-153 m3/hr) with Drill Guide Kit
9090ZG-DG 1/2" (Schedule 40 iron) 1–90 SCFM (2-153 m3/hr) without Drill Guide Kit
9091ZG  3/4" (Schedule 40 iron) 1–120 SCFM (2-204 m3/hr) with Drill Guide Kit
9091ZG-DG 3/4" (Schedule 40 iron) 1–120 SCFM (2-204 m3/hr) without Drill Guide Kit
9092ZG  1" (Schedule 40 iron) 1–160 SCFM (2-272 m3/hr) with Drill Guide Kit
9092ZG-DG 1" (Schedule 40 iron) 1–160 SCFM (2-272 m3/hr) without Drill Guide Kit
9094ZG  1-1/2" (Schedule 40 iron) 2–200 SCFM (3-340 m3/hr) with Drill Guide Kit
9094ZG-DG 1-1/2" (Schedule 40 iron) 2–200 SCFM (3-340 m3/hr) without Drill Guide Kit
9095ZG 2" (Schedule 40 iron) 4-400 SCFM (7-680 m3/hr) with Drill Guide Kit
9095ZG-DG 2" (Schedule 40 iron) 4-400 SCFM (7-680 m3/hr) without Drill Guide Kit
9096ZG 2-1/2" (Schedule 40 iron) 5-500 SCFM (8-850 m3/hr) with Drill Guide Kit
9096ZG-DG 2-1/2" (Schedule 40 iron) 5-500 SCFM (8-850 m3/hr) without Drill Guide Kit
9097ZG 3" (Schedule 40 iron) 12-1200 SCFM (20-2039 m3/hr) with Drill Guide Kit
9097ZG-DG 3" (Schedule 40 iron) 12-1200 SCFM (20-2039 m3/hr) without Drill Guide Kit
9098ZG 4" (Schedule 40 iron) 20-2000 SCFM (34-3398 m3/hr) with Drill Guide Kit
9098ZG-DG 4" (Schedule 40 iron) 20-2000 SCFM (34-3398 m3/hr) without Drill Guide Kit

Buy Now Digital Flowmeter with Wireless Capability (Gateway not included)
Pipe Size/SCFM/M3 Range**
9090Z 1/2" (Schedule 40 iron) 1–90 SCFM (2-153 m3/hr) with Drill Guide Kit
9090Z-DG 1/2" (Schedule 40 iron) 1–90 SCFM (2-153 m3/hr) without Drill Guide Kit
9091Z 3/4" (Schedule 40 iron) 1–120 SCFM (2-204 m3/hr) with Drill Guide Kit
9091Z-DG  3/4" (Schedule 40 iron) 1–120 SCFM (2-204 m3/hr) without Drill Guide Kit
9092Z 1" (Schedule 40 iron) 1–160 SCFM (2-272 m3/hr) with Drill Guide Kit
9092Z-DG 1" (Schedule 40 iron) 1–160 SCFM (2-272 m3/hr) without Drill Guide Kit
9094Z 1-1/2" (Schedule 40 iron) 2–200 SCFM (3-340 m3/hr) with Drill Guide Kit
9094Z-DG 1-1/2" (Schedule 40 iron) 2–200 SCFM (3-340 m3/hr) without Drill Guide Kit
9095Z 2" (Schedule 40 iron) 4-400 SCFM (7-680 m3/hr) with Drill Guide Kit
9095Z-DG 2" (Schedule 40 iron) 4-400 SCFM (7-680 m3/hr) without Drill Guide Kit
9096Z 2-1/2" (Schedule 40 iron) 5-500 SCFM (8-850 m3/hr) with Drill Guide Kit
9096Z-DG 2-1/2" (Schedule 40 iron) 5-500 SCFM (8-850 m3/hr) without Drill Guide Kit
9097Z 3" (Schedule 40 iron) 12-1200 SCFM (20-2039 m3/hr) with Drill Guide Kit
9097Z-DG 3" (Schedule 40 iron) 12-1200 SCFM (20-2039 m3/hr) without Drill Guide Kit
9098Z 4" (Schedule 40 iron) 20-2000 SCFM (34-3398 m3/hr) with Drill Guide Kit
9098Z-DG 4" (Schedule 40 iron) 20-2000 SCFM (34-3398 m3/hr) without Drill Guide Kit

Buy Now Drill Guide Kit
Pipe Size/SCFM/M3 Range
900817 1/2" through 2" (Schedule 40 iron) Drill Guide Kit
901281 2-1/2" (Schedule 40 iron) Drill Guide Kit
900939 3" (Schedule 40 iron) Drill Guide Kit
900871 4" (Schedule 40 iron) Drill Guide Kit

**Calibrated range. Usable range higher. Please consult the factory.
Other sizes and flow rates are available. Contact an Application Engineer at 1-800-903-9247.

Block-Off Rings are available should your Digital Flowmeter need to be removed. See below for models to fit particular Digital Flowmeters.

Buy Now Block-Off Rings
901327 Block-Off Ring for Model 9090Z Digital Flowmeter
901328 Block-Off Ring for Model 9091Z Digital Flowmeter
901329 Block-Off Ring for Model 9092Z Digital Flowmeter
901331 Block-Off Ring for Model 9094Z Digital Flowmeter
901332 Block-Off Ring for Model 9095Z Digital Flowmeter
901333 Block-Off Ring for Model 9096Z Digital Flowmeter
901334 Block-Off Ring for Model 9097Z Digital Flowmeter
901335 Block-Off Ring for Model 9098Z Digital Flowmeter

Other size Block-Off Rings are available. Contact an Application Engineer at 1-800-903-9247.


CAD Library CAD Library FAQs FAQs Presentations Presentations
Videos Videos
QUICK ORDER:
CART INFORMATION:
APPLICATION SEARCH:
 
 
 
 
 
Bookmark and Share
 
  Follow Us
  RSS Wordpress Twitter Facebook