Using the Ultrasonic Leak Detector
| In a plant where loud noise levels exist, it is very difficult to locate leaks by merely listening for them. Most plant noises are in the normal audible range of human hearing, while air escaping from a small orifice is ultrasonic. The ULD can be adjusted to filter out background noise using the three sensitivity settings of X1, X10 and X100 along with an “on/off” thumb wheel for fine sensitivity adjustment. |
 The Model 9061 Ultrasonic Leak Detector quickly pinpoints a costly leak in a noisy, industrial environment. |
| The parabola or tubular extension (shown below) can also be attached to the ULD to mask out intense background noise. The ULD detects only the ultrasonic sounds that are generated. |
 |
 |
 |
 |
| Parabola |
Tubular Adaptor |
Tubular Extension |
Headphones |
Ultrasound is directional in transmission and is loudest at the source. Turbulence created by the air forced through a small orifice generates ultrasonic sound. This emitted sound is called “white noise” and occurs when the air moves from a high pressure area such as a pipe or vessel and escapes to a low pressure area such as the room.
The Ultrasonic Leak Detector converts the turbulent flow to a frequency that can be heard using the headphones. As the ULD moves closer to the leak, more LEDs on the display light to confirm the source of the leak. In some cases, the suspected leak is in a hot area and/or close to moving parts. The tubular extension and parabola make it possible to probe these difficult locations from a distance to isolate the leak.
Find One Leak - Pay For Your Ultrasonic Leak Detector Consider one small leak that is equivalent to a 1/16” diameter hole. At 80 PSIG, it consumes 3.8 SCFM (Standard Cubic Feet per Minute) or 108 SLPM (Standard Liters Per Minute). |
Most large plants know their air cost. If you don’t know your actual cost per 1000 SCF (Standard Cubic Feet), a reasonable average is $.25 per 1000 SCF (28,329 Standard Liters). Dollars consumed per hour = SCFM consumed x 60 minutes x cost/1000 SCF = 3.8 x 60 x .25/1000 = $.06 per hour = $1.37 per 24 hour period = $9.58 per week = $497.95 per year |
 The Model 9061 Ultrasonic Leak Detector comes complete with a hard-shell plastic case, headphones, parabola, tubular adaptor, tubular extension and 9 volt battery. |
| Buy Now |
Ultrasonic Leak Detector |
| Ultrasonic Leak Detector includes a hard-shell plastic case, headphones, parabola, tubular adaptor, tubular extension and 9 volt battery. |
| 9061 |
Ultrasonic Leak Detector |