flow through pipe
In order to maximize performance of our products, EXAIR recommends no greater than a 5psi pressure drop across a given length of air supply pipe.  The chart below shows the maximum air flow volume that can be supplied through a pipe of given length and nominal size, with no more than a 5psi pressure drop across it. 
 
 
 
 

FLOW THROUGH PIPE

100 psig inlet pressure

With max  5 PSIG pressure drop

100'

50'

25'

1/8" NPT

4

6

8

1/4" NPT

10

15

20

3/8" NPT

20

30

40

1/2" NPT

40

55

80

3/4" NPT

80

120

160

1" NPT

150

225

300

1 1/4" NPT

320

480

640