Static Elimination on an accumulation table
Customer had an accumulation table with bottle caps, they would be fed single file to the caping machine. Static was causing the sensors that add more caps to the system to fry. This resulted in the system being down for several hours to replace this sensor. The Model 112106 106" Super Ion Air Knife treated static on the plastic bottle caps prior to them passing by the sensor. This was a custom non-stock length product designed to fit their process.
-
Model 1121108 108" Gen4 Super Ion Air Knife SystemEXAIR's Gen4 Super Ion Air Knife Systems add the Model 7960 Gen4 Power Supply (115 VAC/230 VAC, 50/60 Hz). EXAIR's Gen4 Super Ion Air Knife removes static electricity from plastics, webs, sheet stock and other product surfaces where tearing, jamming or hazardous shocks are a problem. The laminar sheet of air sweeps surfaces clean of static, particulate, dust and dirt. Learn More$6,117.00
-
Model 1122108 108" Gen4 Super Ion Air Knife KitEXAIR's Gen4 Super Ion Air Knife Kits include everything needed to ensure best performance from your Gen4 Super Ion Air Knife: power supply, shim set, filter separator and pressure regulator. The Gen4 Super Ion Air Knife removes static electricity from plastics, webs, sheet stock and other product surfaces where tearing, jamming or hazardous shocks are a problem. Learn More$6,786.00