- Home >
- Model 9061 Ultrasonic Leak Detector
- Presentation
- Application Search
- CAD
- PDFs
- FAQs
Related Info

-
Please Login or Create an Account to Proceed
-
Please Login or Create an Account to Proceed
-
Please Login or Create an Account to Proceed
-
Please Login or Create an Account to Proceed
-
If I simultaneously connect the Summing Remote Display and the Data Logger to the Digital Flowmeter, will the accuracy of the reported air consumption be changed?Can I connect the USB Data Logger to the Summing Remote Display?Can I pulse/cycle the compressed air to your products?What is the temperature limit that the ETC can be exposed to?How do I know how much air EXAIR products can save our company?How can EXAIR’s Ultrasonic Leak Detector help?Can I move the Digital Flow Meter from place to place?How does the Digital Flow Meter fit with my compressed air savings program?Your catalog offers Digital Flowmeters for schedule 40 steel pipe sizes from 1/2" through 6". Do you offer models for copper pipe?What are the operating modes for the Summing Remote Display?How do I change the mode of operation on the Summing Remote Display?How long is the cable that connects the Summing Remote Display to the Digital Flowmeter?Is it possible to have my Digital Sound Level Meter calibrated?Can the EFC control 2 solenoid valves?Can I make the Digital Flowmeter portable?What is the range of the Digital Flowmeters?Can the Digital Flowmeter be used with a Data Acquisition system?How far can the Summing Remote Display for the Digital Flowmeter be mounted from the meter?What sound level do your products produce?Is the EFC (Electronic Flow Control) available in different voltages?Why do I need an EFC?How do I know which EFC to choose?
- Locates leaks in air, steam and non-flammable gas systems including pipes, fittings, valves, cylinders and pressure vessels
- Finds the source of bearing and gear wear
- Locates arcing in an electrical system
- Detects refrigeration and air conditioning system leaks
- Locates leaks in brake systems, tubes, tires and radiators
- Senses cracks in moving rubber v-belts
- Detects leaks in vacuum systems
- Checks condition of engine seals
- Detects any pressurized air leak up to 20 ft (6.1m) away.
- Converts ultrasound to an audible frequency
- LED display confirms the leak location
- Detects leaks in noisy industrial environments
- Sensitivity controls provide accurate dtection
- Not affected by contaminants or windy conditions
- Includes accessories to detect leaks in hard to reach areas
- Rugged carrying case
- Meets ASTM standards
Features
Applications
Features
Advantages
More Information

What is Ultrasound?

Ultrasonic sound is a range of sound that is above human hearing capacity. Most people can hear frequencies from 20 Hz to 20 kHz. Sound from 20 KHz to 100 kHz can not be heard and is called "ultrasonic". The Model 9061 Ultrasonic Leak Detector converts ultrasonic sound emissions to a range that is audible to people. (The sound generated by the ULD is 32 times lower in frequency than the sound that is received.)
Find One Leak - Pay for Your Ultrasonic Leak Detector

Consider one small leak that is quivalent to a 1/16" (1.6mm) diameter hole. At 80 PSIG (5.5 BAR), it consumes 3.8 SCFM or 108 SLPM.
Most large plants know ther air cost. If you don't know your actual cost per 1,000 SCF, a reasonable average is $0.25 per 1,000 SCF (28,329 SL).
Dollars consumed per hour = SCFM consumed x 60 minutes x cost/1,000 SCF
= 3.8 x 60 x $0.25/1,000
= $0.06 per hour
= $1.44 per 24 hour period
= $524.16 per year
Efficiency Lab
Does your company currently use a blowoff product similar to EXAIR’s that you’d like us to evaluate? Ship it to the EXAIR Efficiency Lab! Our qualified staff will test it for FREE, using EXAIR’s calibrated testing equipment. We’ll compare the performance of your existing product (air consumption, effectiveness, noise levels, efficiencies, etc) with the EXAIR Intelligent Compressed Air® products. The results will be published in a comprehensive report that includes a cost savings analysis. For most applications, EXAIR products can help you improve your efficiency AND typically pay for themselves in a matter of weeks.
To participate in our Efficiency Lab testing, please complete this Product Efficiency Survey to give us the details about your current application and blowoff set up. You can also feel free to contact an Application Engineer for more information at (800) 903-9247 or (513) 671-3322.
After completing the form, your product can be shipped to:
Efficiency Lab
EXAIR Corporation
11510 Goldcoast Dr.
Cincinnati, OH 45249-1621This offer is available to all customers in the U.S. and Canada only. Some restrictions might apply.
Products must be shipped to EXAIR freight prepaid. EXAIR will pay the return shipping via UPS ground.
If you cannot send in your product, fill out this Product Efficiency Survey to give us the details about your current application and we will estimate the savings for you.
Images
-
The ULD will quickly locate costly leaks in noisy environments. -
The ULD's included fittings make it easy to locate leaks in hard-to-reach areas -
The full ULD system includes ULD, attachments, headphones, and 9 volt battery -
The Ultrasonic Leak Detector -
It pays to have ULD to detect costly leaks!
Available + -
Features + -
Related Products + -
My Cart + -
You have no items in your shopping cart.