Delay Curing Time
Company manufactures specialty lighting. They dispense a two part silicone adhesive to their product. The material sets up within the dispenser within an hour or so, necessitating shutting down production and cleaning out the dispenser and recharging it. By cooling the dispensing head with a Model 3204 Vortex Tube, cure time went from a couple of hours to a couple of shifts which eliminated it from setting up inside the dispenser. This increased production, provided a savings in labor and lost material.