Model P9097-DG-DAT Pressure Sensing Digital Flowmeter for 3" Schedule 40 Iron Pipe without Drill Guide Kit and with Data Logger
Advantages
- Easy to install
- Data Logger included
- Easy to switch between Pressure, SCFM and M3/hr readings
- Pressure, Metric or English unit displays can be specified for all model sizes.
- No moving parts
- Sensitive at low flows
- No calibration or setup required
- Includes all components for installation
- Models from 2" thru 8" Schedule 40 iron pipe in stock
- Models are available for sizes 25mm thru 101mm in aluminum pipe
- Models are available for sizes 2" thru 4" in copper pipe
Pressure Sensing Digital Flowmeter Models
- Models are available for 2" through 8" Schedule 40 iron pipe.
- Models are available for 50mm thru 101mm aluminum pipe.
- Models are available for 2" thru 4" copper pipe.
- Pressure, Metric or English unit displays can be specified for all model sizes.
- Models can be ordered with or without drill guides.
Accessories
USB Data Logger
EXAIR's award-winning USB Data Logger Model 9147 connects directly to the Digital Flowmeter and is simple to use. It can be configured to record flow rate from once per second to once every 12 hours. Data can be read with included software or imported into a spreadsheet.
Summing Remote Display
The Summing Remote Display allows remote viewing of Digital Flowmeter data. Additional features include: current air consumption, usage for the previous 24 hours, and total cumulative usage.
Drill Guide Kit
The Drill Guide Kit provides precise positioning to drill the holes in your pipe necessary for the probes on the Digital Flowmeter.
Block-Off Ring
The Block-Off Ring is necessary should you decide to remove or relocate your Digital Flowmeter.
Specifications - Digital Flowmeter | |
Accuracy | PRESSURE: +/-2 PSIG maximum. +/- PSIG at 68. |
Operating Pressure | 200 PSIG maximum on Sch. 40 iron and on Type L Copper below 3". Consult EXAIR for other materials and at higher pressures. |
Input Power | 250 mA at 24 VDC |
Output Resistance | 600 Ohms maximum |
Wetted Materials | Stainless steel, gold, thermal epoxy and Viton |
Ring Material | Aluminum |
Display | Four-digit LED display |
Response Time | One second to 63% of change in value at flows above 30% of range. |
Pressure Range | 0-145 PSIG operating range 200 PSIG maximum 145 PSIG full scale of mA output For best accuracy, avoid pressures above 145 PSIG |
Compliance | CE and RoHS |
Note: For use with compressed air and nitrogen only. |
Dimensions and Flow Range – Pressure Sensing Digital Flowmeter – Schedule 40 Iron Pipe |
|||||
A |
|||||
Series | Pipe Size |
in | mm | Flow Range | |
P9095 | 2" | 5.34 | 136 | 6-600 SCFM (10.2-1020 m3/hr) | |
P9096 | 2 1/2" | 6.09 | 155 | 8-800 SCFM (13.6-1359 m3/hr) | |
P9097 | 3" | 6.71 | 171 | 12-1200 SCFM | |
P9098 | 4" | 7.71 | 196 | 20-2000 SCFM | |
P9099 | 5" | 8.84 | 224 | 30-3000 SCFM (51-5100 m3/hr) | |
P90100 | 6" | 9.84 | 250 | 50-5000 SCFM | |
P90101 | 8" | 11.84 | 301 | 100-6000 SCFM |
Dimensions and Flow Range – Pressure Sensing Digital Flowmeter – Type L Copper Pipe |
|||||
|
A |
||||
Series | Pipe Size |
in | mm | Flow Range | |
P9095CU | 2" | 5.09 | 129 | 6-600 SCFM (10.2-1020 m3/hr) | |
P9096CU | 2 1/2" | 5.84 | 148 | 8-800 SCFM (13.6-1359 m3/hr) | |
P9097CU | 3" | 6.34 | 161 | 10-1000 SCFM (17-1699 m3/hr) | |
P9098CU | 4" | 7.34 | 186 | 20-2000 SCFM (34-3398 m3/hr) |
Dimensions and Flow Range - Pressure Sensing Digital Flowmeter – Aluminum Pipe |
|||||
|
A |
||||
Series | Pipe Size |
in | mm | Flow Range | |
P91050 | 50mm | 5.1 | 129 | 6-600 SCFM (10.2-1020 m3/hr) | |
P91063 | 63mm | 5.6 | 142 | 8-800 SCFM (13.6-1359 m3/hr) | |
P91076 | 76mm | 6.3 | 161 | 10-1000 SCFM (17-1699 m3/hr) | |
P91101 | 101mm | 7.3 | 186 | 20-2000 SCFM (34-3398 m3/hr) |
Efficiency Lab
Does your company currently use a blowoff product similar to EXAIR’s that you’d like us to evaluate? Ship it to the EXAIR Efficiency Lab! Our qualified staff will test it for FREE, using EXAIR’s calibrated testing equipment. We’ll compare the performance of your existing product (air consumption, effectiveness, noise levels, efficiencies, etc) with the EXAIR Intelligent Compressed Air® products. The results will be published in a comprehensive report that includes a cost savings analysis. For most applications, EXAIR products can help you improve your efficiency AND typically pay for themselves in a matter of weeks.
To participate in our Efficiency Lab testing, please complete this Product Efficiency Survey to give us the details about your current application and blowoff set up. You can also feel free to contact an Application Engineer for more information at (800) 903-9247 or (513) 671-3322.
After completing the form, your product can be shipped to: Efficiency Lab, EXAIR, 11510 Goldcoast Dr., Cincinnati, OH 45249-1621
This offer is available to all customers in the U.S. and Canada only. Some restrictions might apply.
Products must be shipped to EXAIR freight prepaid. EXAIR will pay the return shipping via UPS ground.
If you cannot send in your product, fill out this Product Efficiency Survey to give us the details about your current application and we will estimate the savings for you.